| Power
tranf: DC: RXTUG 22H; U1=(24-250VDC); U2=(±12/18/24VDC) |
| Code: 1MRK000
592-A |
| RXTTE4;
U=110VAC,
1A |
| Code: 1MRK002
108-BA |
| RXHL421;
U=110VAC,
1A |
| Code:
1MRK000 322-FG replaced
by 1MRK001975-AB |
| Thermorcoupler
type K ( NiCr/Ni ) |
| Type
: TSH210 (Y0.A1.H30.M2.N4.Y00.K1.T2.A4.Y1) |
| Range :
0 – 1200 °C |
| Sheath
length : 1000 mm |
| Sheath
diameter : 22 mm |
| Metallic
protective tube to 1200 °C |
| Material
No. 1.4841 |
| Electronic
timer type. CT-MXS.22 (1SVR 630 030 R3300) |
| Type
:SDCD POW 4 |
| SW:
831C0415, 3APT 315100R1001 |
| T
3151001001 T831C0419 |
| Electronic
timer type. CT-MXS.22 (1SVR 630 030 R3300) |
| Type
:SDCD POW 4 |
| SW:
831C0415, 3APT 315100R1001 |
| T
3151001001 T831C0419 |
|
| Correct: Sensor 871C
2 wire namuc
#12x30 |
| Sensor 817C
2 wire namuc #12x30 |
| Type
:SDCD POW 4 |
| SW:
831C0415, 3APT 315100R1001 |
| T
3151001001 T831C0419 |
| Standard
type 12KV
4KA |
| Fixed
type VD4 1240-40 |
| SNo:
3728013 |
| Standard
type 12KV 4KA |
| Handcart
type VD4
1240-40 |
| SNo:
3728013 |
| M2QA
160 M8B |
| (5.5KW;
8 POLE = 750 r/min; 3P 380V; FOOT + FLANGE IM B35; 50/60 Hz; IP 55) |
| 125-140kg |
| 1SDA051371R1 |
| Code:10061464 |
| Model:AUX-C
3Q1SY-CABLED 250VAC/DC T1/3 |
|
| Auxiliary
contact AUX-C 3Q 1SY 250VAC/DC
1SDA051371R1 |
| 1SDA051383R1 |
| Code:10061739 |
| Model:RHE
NORMAL FOR F/P T1/3 |
|
| Rotary
handle 1SDA051383R1 |
| 1SDA054929R1 |
| Code:10064999 |
| Model:RHE
NORMAL FOR F/P T4/5 |
|
| Rotary
handle 1SDA054929R1 |
| OT25ET3 |
|
| Switch
OT25ET3-32A |
| ACS
550-01-06A9-4 |
| ***Panel
Included in English |
| SEW
Inverter |
| NQAE
J71M4B |
| NQAE
J07230-BSA |
| BAR-300/TH02
- Ordering # 7962545 |
| Can not
find, Pls confirm??? |
| ACS
143-H75-3 |
| (ACS143H753)
could not confirm; please take a nameplate |
| MC07A030-5A3-4-00 |
| Model: 266
GSH-D-K-B-N-B-H-E2-L1-B1-S2-M5 |
| 266GSH -
High performance Gauge Pressure Transmitter |
| - Base
accuracy 0.06% |
| Sensor -
Span Limits: 10 and 1000 kPa (0.1 and 10 bar, 1.45 and 145 psi) |
| Calibration
range: 0 -> 0.50MPa |
| Process
Connection Material/Type: AISI 316L ss / 1/2-14 NPT female |
| Housing
Material / E-Connection: Aluminium alloy (barrel version) M20 x 1.5 |
| Output:
HART digital communication and 4 to 20 mA |
| Hazardous
area certifications: ATEX Explosion Proof Group II Category 1/2 |
| G Ex d
IIC T6 and Group II Category 1/2 D Ex tD A21 IP67 T85° C |
| Integral
LCD: digital LCD controlled display |
| Operating
manual: English |
| Model: 266
GSH-L-K-B-N-B-H-E2-L1-S2-M5 |
| 266GSH -
High performance Gauge Pressure Transmitter |
| -
Base accuracy 0.06% |
| Sensor -
Span Limits: 2.5 and 250 kPa (25 and 2500 mbar, 10 and 1000 |
| inH2O) |
| Calibration
range: 0 -> 0.10MPa |
| Process
Connection Material/Type: AISI 316L ss / 1/2-14 NPT female |
| Housing
Material / E-Connection: Aluminium alloy (barrel version) M20 x 1.5 |
| Output:
HART digital communication and 4 to 20 mA |
| Hazardous
area certifications: ATEX Explosion Proof Group II Category 1/2 |
| G Ex d
IIC T6 and Group II Category 1/2 D Ex tD A21 IP67 T85° C |
| Integral
LCD: digital LCD controlled display |
| Operating
manual: English |
Không có nhận xét nào: